• Contact us
  • E-Submission
ABOUT
BROWSE ARTICLES
JOURNAL POLICIES
FOR CONTRIBUTORS

Page Path

2
results for

"Jeong Yoon Yim"

Filter

Article category

Keywords

Publication year

Authors

"Jeong Yoon Yim"

Case Report

[English]
A Case of Pacemaker Syndrome, Proved by Cardiac Catheterization
Hye Young Son, Jeong Yoon Yim, Sung Kee Ryu, Hong Keun Cho, Si-Hoon Park, Gil Ja Shin
Ihwa Ŭidae chi 1997;20(2):159-164.   Published online July 24, 2015
DOI: https://doi.org/10.12771/emj.1997.20.2.159

The pacemaker syndrome is a complex of clinical signs and symptoms related to the adverse hemodynamic and electrophysiologic consequence of ventricular pacing in the absence of other cause.

The following illustrates a case of pacemaker syndrome proven by cardiac catheterization. A 64-year-old female patient who had been previously managed with single chamber pacemaker(VVI mode) due to sick sinus syndrome, suffered from chest discomfort, headache, dizziness, lightheadedness.

We thought that she suffered from pacemaker syndrome and changed single chamber pacing to dual chamber pacing. At that time we performed cardiac catheterization perioperatively.

Pulmonary capillary wedge pressure, amin pulmonary arterial pressure, right atrial pressure and right ventricular pressure were normalized after the change and she didn't feel any symptoms.

  • 58 View
  • 0 Download
Original Article
[English]
The Comparison of HP™ Test, a New Domestically Manufactured Rapid Urease Test, with CLO™ Test
Jeong Yoon Yim, Young Mee Ahn, Doe Young Kim, Il Whan Moon
Ihwa Ŭidae chi 1999;22(4):213-217.   Published online December 31, 1999
DOI: https://doi.org/10.12771/emj.1999.22.4.213

Although CLO test is one of the most commonly used rapid urease test for the diagnosis of Helicobacter(H.) pylori infection. Recently a Korean company, Jongkeundang, has succeeded in manufacturing the rapid urease test and named it as HP™ test. The advantages of HP test are to have two agar gels in a plate and react faster in despite of same cost with CLO test. We performed this study to compare the results of the HP test with those of the CLO test and know if there is any advantage of using two biopsy samples instead of using only one sample.

One hundred and eight patients underwent gastroscopy and two biopsy specimens from the greater curvature of the antrum was used for HP test and CLO test. Another biopsy specimen from lesser curvature of midbody was used for HP test. We read them at 20min, 1hour, 3hours, and 24hours.

The positive rate of HP test in antrum was 49.1%(53/108) which was the same as CLO test in antrum. The concordance rate of the results of two tests in the same site(antrum) were 98.2%. In terms of a time change to a positive test, both tests were not significantly different with each other. ; 3hour positive rate of HP test was 94.4% and that of HP test was 92.5%. Four patients(5.6%) performed HP test had positive results after 2hours known final reading time.

The positive rate of HP test in body was 52.8%(57/108) and that of HP test in antrum or body was 53.7%(58/108). The concordance rate of the results of antrum and body in HP test was 94.4%. Five of the negative HP test in antrum(4.7%) had positive results in gastric body. They were negative CLO test in antrum.

In conclusion, HP test was thought to be as valuable as CLO test for the diagnosis of H. pylori infection and has a merit of decreasing sampling error by using two samples, even though it is a little. However, It had not quicker time to positivity than CLO test and might have false negative results if it were read at 2hours after reaction. So, Final reading time should be reevaluated.

  • 39 View
  • 0 Download
TOP